Menu
Your Cart

24 V 10 A 240 W Switching Power Supply with Cooling Fan

24 V 10 A 240 W Switching Power Supply with Cooling Fan
24 V 10 A 240 W Switching Power Supply with Cooling Fan
Out of Stock
24 V 10 A 240 W Switching Power Supply with Cooling Fan
24 V 10 A 240 W Switching Power Supply with Cooling Fan
24 V 10 A 240 W Switching Power Supply with Cooling Fan
14.99€
Ex Tax: 12.39€
  • Stock: Out of Stock
  • Model: PSU-24v10A

Model:

12V 5A 60W

12V 5A 60W

12V 10A 120W

12V 10A 120W

12V 15A 180W

12V 15A 180W

12V 20A 250W Fan

12V 20A 250W Fan

12V 33A 400W

12V 33A 400W

12V 40A - 500W

12V 40A - 500W

24V 10A 240W

24V 10A 240W

24V 15A 360W

24V 15A 360W

24V 20A 500W

24V 20A 500W

24V 25A 600W

24V 25A 600W

24V 33A 800W

24V 33A 800W

36V 10A 360W

36V 10A 360W

48V 10A 500W

48V 10A 500W

Product out of stock
This product is out of stock, we will try to replenish it as soon as possible. You can request a notice by clicking on the green button (except discontinued products).

AC/DC switching power supply with a 24 V output and a maximum nominal current of 10 A, equivalent to 240 W. It is intended for 3D printers, small CNC machines, automation systems, lighting and other equipment operating entirely from 24 V.

Electrical specifications

  • Output voltage: 24 V DC.
  • Maximum nominal current: 10 A.
  • Nominal power: 240 W.
  • Selectable mains input for approximately 110 or 220-230 V AC.
  • Specified input frequency: 50/60 Hz.
  • Integrated cooling fan.
  • Ventilated metal enclosure.
  • Terminal cover.
  • Fine output-voltage adjustment potentiometer.

24 V 10 A switching power supply with fan, mains selector and connection terminals

Applications and compatibility

It may be used with 24 V equipment whose maximum consumption, including heaters, motors, fans and electronics, remains within the power-supply capacity with suitable margin.

Compatibility with a particular printer must not be assumed from its 24 V rating alone. Power, peak current, connections, dimensions, ventilation and behaviour during simultaneous heating and movement must also be checked.

Declared protection functions

  • Short-circuit protection.
  • Overload protection.
  • Overvoltage protection.
  • Overtemperature protection.
  • Electromagnetic-interference filtering.

These declared functions do not replace fuses, protective earthing, correctly rated wiring or the machine's own safety devices.

Safe installation

  • Select the correct mains-input position before connection.
  • Connect line, neutral and protective earth to the marked terminals.
  • Bond the metal enclosure to protective earth.
  • Check output polarity before powering the electronics.
  • Use terminals, fuses and wiring suitable for the expected current.
  • Do not cover the ventilation openings or obstruct the fan.
  • Install inside an enclosure protected against accidental contact.
  • Perform all wiring with the supply disconnected.

This unit operates from hazardous mains voltage and should only be installed by a suitably competent person. An incorrectly set input selector may damage both the power supply and connected equipment.

Package contents

  • 1 × 24 V, 10 A, 240 W switching power supply.

Write a review

Note: HTML is not translated!
Bad Good
Captcha

EQUIPMENT START UP:

  1. Check that the mains voltage matches the input selected for the source (110/220v)
  2. Connect the power supply to the mains to check the output voltage (12/24v)
  3. The output voltage is adjustable, if it differs from the one you want for your application you can turn the regulator, preferably with the equipment off. Never use a metal screwdriver with the equipment on to make this adjustment.
  4. (Depending on the model) This power supply has a regulated fan, it will turn when it has load, check periodically and in the first use that the fan is activated correctly.


SAFETY INSTRUCTIONS COMPACT POWER SUPPLY:

  • Dimension the installation correctly, with an appropriate safety factor.
  • Never block or hinder the fan's air output. 
  • Before connecting the equipment to the power supply, check that the available mains voltage corresponds to the voltage value of the equipment.
  • Connect the mains cable of the equipment to a grounded power outlet.
  • Do not place the equipment on wet or damp surfaces.
  • Do not expose the equipment to direct sunlight or extreme temperatures.
  • Do not expose the equipment to moisture.
  • Do not exceed the maximum input voltage allowed.
  • Comply with the warning and information labels on the equipment.
  • Wear dry clothes and rubber shoes to ensure insulation.
  • Do not insert metal objects into the equipment through the ventilation slots.
  • Do not place containers full of liquids on the equipment (danger of short circuit in case of shock).
  • Do not use the equipment near strong magnetic fields (motors, transformers, etc.).
  • Do not expose the equipment to strong shocks or vibrations.
  • Allow the unit to stabilize at room temperature before taking measurements (important for accurate measurement).
  • Do not modify the equipment in any way.
  • The equipment must be opened for service or repair by qualified personnel. It is recommended that repair work be carried out in the presence of a second person trained to perform first aid if necessary.
  • Keep the power source away from children.
  • Before cleaning the box, pull out the plug from the socket. Clean only with mild household cleaner. Make sure that no water gets inside the equipment to avoid possible short circuits and damage to the equipment.