Menu
Your Cart

Compact 12 V 10 A 120 W switching power supply

Compact 12 V 10 A 120 W switching power supply
Compact 12 V 10 A 120 W switching power supply
Compact 12 V 10 A 120 W switching power supply
Compact 12 V 10 A 120 W switching power supply
Compact 12 V 10 A 120 W switching power supply
11.85€
Ex Tax: 9.79€
5 or more 10.99€
  • Stock: 28
  • Model: PSU-12v10a120w

Model:

12V 5A 60W

12V 5A 60W

12V 10A 120W

12V 10A 120W

12V 15A 180W

12V 15A 180W

12V 20A 250W Fan

12V 20A 250W Fan

12V 33A 400W

12V 33A 400W

12V 40A - 500W

12V 40A - 500W

24V 10A 240W

24V 10A 240W

24V 15A 360W

24V 15A 360W

24V 20A 500W

24V 20A 500W

24V 25A 600W

24V 25A 600W

24V 33A 800W

24V 33A 800W

36V 10A 360W

36V 10A 360W

48V 10A 500W

48V 10A 500W

Fast shipping from Spain
Delivery from 24 hours and free shipping available in mainland Spain.
Stock on hand
Shipped quickly from Spain, with a full VAT invoice.
Secure & flexible payment
Pay by card, PayPal or bank transfer.
Expert technical support
Over 10 years helping customers with components and compatibility.

A compact 12 V, 10 A, 120 W AC/DC switching power supply for electronics, LED lighting, motors, CNC systems and 12 V 3D-printing equipment. Its perforated metal enclosure provides passive cooling and makes it suitable for integration into machine frames and electrical enclosures.

It can power a 3D printer without a heated bed, a printer whose bed has a separate supply, or any machine whose combined load remains within the 10 A nominal limit. Include the controller, motors, heaters, fans, lighting and accessories when calculating the total.

Technical specifications

FeatureValue
TypeSingle-output AC/DC switching power supply
Selectable input100-120 V AC, 60 Hz / 200-240 V AC, 50 Hz
Nominal output12 V DC
Maximum nominal current10 A
Nominal power120 W
CoolingPassive cooling through a perforated metal enclosure
Output adjustmentFine adjustment through V ADJ
ConnectionsTerminals for L, N, earth, V- and V+
Contents1 power supply

Integrated protection

  • Short-circuit protection.
  • Overload protection.
  • Overvoltage protection.
  • Overtemperature protection.
  • EMI filtering to reduce electromagnetic interference.
  • Full-load operation test.

Compact 12 V 10 A switching power supply with ventilated enclosure and covered terminal block

Calculating the load

Current in a 12 V system can be estimated with current = power / 12:

Total loadApproximate current at 12 V
60 W5 A
84 W7 A
96 W8 A
120 W10 A nominal maximum

Allow headroom for start-up peaks, ambient temperature and later expansion. If more current is required, see the compact 12 V, 20 A, 250 W fan-cooled power supply.

Mains and 12 V connections

This unit connects directly to mains electricity. Installation must be performed by a suitably competent person, with the supply disconnected, protected against accidental reconnection and mounted inside a ventilated enclosure that prevents access to its terminals.
  1. Input selector: set it to 220/230 V before use on a 230 V, 50 Hz supply. An incorrect setting may damage the power supply and connected equipment.
  2. AC input: connect live to L, neutral to N and protective earth to the earth-marked terminal. The metal enclosure must be properly earthed.
  3. DC output: connect positive to V+ and negative to V-. V- is not protective earth.
  4. Verification: measure output voltage and polarity with a multimeter before connecting electronics.

V ADJ provides fine adjustment around 12 V and must not be used to convert the unit to a different nominal voltage. Every connected device must be designed for 12 V or explicitly accept it.

Safe machine integration

  • Install in a dry, ventilated location protected from metal objects, conductive dust and swarf.
  • Keep every cooling opening clear and provide free space around the enclosure.
  • Fit a suitable switch, input overcurrent protection, strain relief and properly terminated wiring.
  • As a guide for short internal machine runs, 1.5 mm² output cable provides a conservative starting point for up to 10 A; final sizing must consider length, voltage drop, temperature, bundling and local rules.
  • Do not connect multiple supplies in series or parallel unless the specific installation documentation permits it.

A detachable input can be built with an IEC inlet and switch and a Schuko to IEC C13 mains lead, together with suitable protection and wiring.

Firmware

The power supply has no dedicated Marlin, Klipper or RepRapFirmware setting. Keep hotend and heated-bed thermal protection enabled. Repeat PID calibration only if the change in power delivery produces a meaningful change in heater response.

Write a review

Note: HTML is not translated!
Bad Good
Captcha

EQUIPMENT START UP:

  1. Check that the mains voltage matches the input selected for the source (110/220v)
  2. Connect the power supply to the mains to check the output voltage (12/24v)
  3. The output voltage is adjustable, if it differs from the one you want for your application you can turn the regulator, preferably with the equipment off. Never use a metal screwdriver with the equipment on to make this adjustment.
  4. (Depending on the model) This power supply has a regulated fan, it will turn when it has load, check periodically and in the first use that the fan is activated correctly.


SAFETY INSTRUCTIONS COMPACT POWER SUPPLY:

  • Dimension the installation correctly, with an appropriate safety factor.
  • Never block or hinder the fan's air output. 
  • Before connecting the equipment to the power supply, check that the available mains voltage corresponds to the voltage value of the equipment.
  • Connect the mains cable of the equipment to a grounded power outlet.
  • Do not place the equipment on wet or damp surfaces.
  • Do not expose the equipment to direct sunlight or extreme temperatures.
  • Do not expose the equipment to moisture.
  • Do not exceed the maximum input voltage allowed.
  • Comply with the warning and information labels on the equipment.
  • Wear dry clothes and rubber shoes to ensure insulation.
  • Do not insert metal objects into the equipment through the ventilation slots.
  • Do not place containers full of liquids on the equipment (danger of short circuit in case of shock).
  • Do not use the equipment near strong magnetic fields (motors, transformers, etc.).
  • Do not expose the equipment to strong shocks or vibrations.
  • Allow the unit to stabilize at room temperature before taking measurements (important for accurate measurement).
  • Do not modify the equipment in any way.
  • The equipment must be opened for service or repair by qualified personnel. It is recommended that repair work be carried out in the presence of a second person trained to perform first aid if necessary.
  • Keep the power source away from children.
  • Before cleaning the box, pull out the plug from the socket. Clean only with mild household cleaner. Make sure that no water gets inside the equipment to avoid possible short circuits and damage to the equipment.