Menu
Your Cart

24 V 40 W Ø6 × 20 mm heater cartridge for hotends

24 V 40 W Ø6 × 20 mm heater cartridge for hotends
24 V 40 W Ø6 × 20 mm heater cartridge for hotends
24 V 40 W Ø6 × 20 mm heater cartridge for hotends
24 V 40 W Ø6 × 20 mm heater cartridge for hotends
24 V 40 W Ø6 × 20 mm heater cartridge for hotends
0.95€
Ex Tax: 0.79€
10 or more 0.85€
50 or more 0.75€
  • Stock: 72
  • Model: Resistencia 24V 40W

Model:

12V 40W

12V 40W

12V 50W

12V 50W

24V 40W

24V 40W

24V 50W

24V 50W

24V 60W

24V 60W

24V 70W

24V 70W

24V 80W

24V 80W

Fast shipping from Spain
Delivery from 24 hours and free shipping available in mainland Spain.
Stock on hand
Shipped quickly from Spain, with a full VAT invoice.
Secure & flexible payment
Pay by card, PayPal or bank transfer.
Expert technical support
Over 10 years helping customers with components and compatibility.

24 V, 40 W cylindrical heater cartridge for hotend blocks with a nominal 6 mm heater bore. This configuration is widely used in 24 V V6-style hotends and is suitable as a replacement when dimensions, voltage, power, cable length and electrical connection all match.

The cartridge has a metal sheath, a ceramic heating core and approximately one metre of red heat-resistant cable. It is supplied without a printer-specific connector.

24 V 40 W heater cartridge with metal sheath and red heat-resistant cable

Technical specifications

SpecificationValue
Rated voltage24 V DC
Rated power40 W
Nominal dimensionsØ6 × 20 mm
Cable lengthApproximately 1 m
Outer sheathStainless steel
Heating coreCeramic
Calculated rated currentApproximately 1.67 A
Calculated nominal resistanceApproximately 14.40 Ω when cold

Compatibility

  • 24 V V6 hotends and derivative blocks with an actual Ø6 × 20 mm cartridge bore.
  • Volcano heater blocks and custom systems with equivalent mounting, retention and electronics.
  • Original Prusa MK3 and MK3S: it matches the documented nominal heater voltage and power, but cable length, termination, connector and printer revision must be checked before treating it as a replacement.

Do not assume compatibility with Original Prusa MK4, MK3.9, CORE One or other Nextruder machines. It is also unsuitable for E3D Revo, Bambu Lab, Phaetus RAPIDO, Dragon ACE, CHC and other hotends using integrated heaters or a different geometry.

A 24 V cartridge must not be installed as a direct replacement in a 12 V machine. At 12 V it would produce approximately one quarter of its rated power and could trigger heating errors.

Checks and installation

  1. Confirm that the hotend output operates at 24 V.
  2. Measure the cold, disconnected cartridge. A reading near 14.4 Ω helps identify the 24 V/40 W version.
  3. Check that its diameter and length allow it to be fully inserted into the block.
  4. Secure it correctly without puncturing or deforming its metal sheath.
  5. Route and secure the cable, avoiding pulling, tight bends, abrasion and contact with the nozzle or heater block.
  6. Fit a suitable connector where required, following the machine pinout and retention system.

Never power the cartridge outside the heater block. Before commanding heat, verify that the temperature sensor reports a stable ambient reading. Supervise the first test and begin with a low target.

Firmware tuning

  • Marlin: run M303 E0 C8 S210 U1, adapting the target to normal use, followed by M500. MPC configurations use their corresponding procedure, commonly M306 T.
  • Klipper: run PID_CALIBRATE HEATER=extruder TARGET=210, followed by SAVE_CONFIG.
  • RepRapFirmware: run M303 H1 S210 for a hotend configured as H1 and incorporate the resulting M307 command.

The heater cartridge does not measure temperature. The thermistor, PT100, PT1000 or other sensor must be configured separately, with limits appropriate for the complete hotend.